CCK-8 detection kit - cell activity detection method - Database & Sql Blog Articles

Test - lowercase jpg
Kaixin micro test
Test probe P100-M3

The advantage of the CCK-8 test kit is that it does not require DMSO to dissolve, and is non-toxic, and operates.

Safe again

Convenient, it is very convenient and efficient for cell activity detection, cell proliferation and toxicity detection.

Details of the operation of the CCK-8 test kit in these areas, and how to choose the appropriate CCK-8 test kit?


CCK-8 Test Kit -

Cell activity assay

1. Inoculate a cell suspension (100 μl/well) in a 96-well plate. Place the plate in the incubator for a period of time (37 ° C, 5% CO)

2

).

2. Add 10 μl of CCK-8 solution to each well (be careful not to create bubbles in the wells that will affect the OD reading).

3. Incubate the plates in the incubator for 1-4 hours.

4. Determine the absorbance at 450 nm using a microplate reader.

Note: If the OD value is not measured temporarily, you can add it to each well.

10 μl 0.1 M HCL solution or 1% w/v SDS solution

And cover the culture plate in the dark to save at room temperature. The absorbance does not change within 24 hours.

CCK-8 Test Kit -

Cell proliferation-toxicity test

1. Dispense 100 μl of cell suspension (2000-5000 cells) in a 96-well plate. Place the plate in the incubator for 24 hours (37 ° C, 5% CO)

2

).

2. Add 10 μl of different concentrations of the test substance to the plate.

3. Incubate the plates in the incubator for a suitable period of time (eg, 6, 12, 24 or 48 hours).

4. Add 10 μl of CCK-8 solution to each well (do not create bubbles in the wells that will affect the OD reading).

5. Incubate the plates in the incubator for 1-4 hours.

6. Determine the absorbance at 450 nm using a microplate reader.

Note: If the OD value is not measured temporarily, you can add it to each well.

10 μl 0.1 M HCL solution or 1% w/v SDS solution

And cover the culture plate in the dark to save at room temperature. The absorbance does not change within 24 hours. If the substance to be tested is oxidizing or reducing, replace the medium with fresh medium (removal of the medium and wash the cells twice with medium, then add new medium) to remove the effects of the drug. Of course, in the case where the influence of the drug is relatively small, the medium can be directly subtracted from the blank absorption after the drug is added to the medium.

How to choose the right CCK-8 test kit?

The [CCK-8] cell proliferation/toxicity test kit currently available on the market is available in domestic or imported products. The domestically packaged CCK-8 kit has insufficient quality stability. The CCK-8 kits, which are native to domestic laboratories, have some good test results and are difficult to control in batch stability. As for the imported brands that supply CCK-8 kits, there are not many imported brands. Even Abcam, Thermo, Sigma and other brands can not provide CCK-8 kits, while other brands are far less expensive than Abbkine products.

As the first cell analysis flagship product of the Abbkine brand,

Cell Counting Kit (CCK-8)

Abbkine R&D engineers have invested a lot of money in continually exploring and optimizing the best formulas. Each effort is only to make scientific research workers more simple, efficient and stable access to valuable scientific research data.

Tel

Product Name and Description Item No. Product Description

Cell Counting Kit-8 (CCK-8)

KTC011001 Details

Detection is very convenient. Only one tube of CCK-8 solution containing WST-8 has been prepared in the kit, no need to perform any preparation and other operations. No isotope is required and all detection steps are performed in the same 96-well plate. It is not necessary to wash the cells, it is not necessary to collect the cells, and there is no need to take extra steps to dissolve the formazan. Can be used for the detection of large quantities of samples.

"CCK-8 Test Kit: Comprehensive Comparison of Cell Proliferation and Toxicity Detection"

Brand (specification)

Abbkine

Sigma

Dojindo

100 times

200 yuan

703.17 yuan

350 yuan

500 times

640 yuan

2779.92 yuan

890 yuan

2000 times

2050 yuan

13899.6 yuan (3000 times)

——

10,000 times

7180 yuan

——

8380 yuan

As the general agent of Abbkine China, Amy Jiejie will provide customers with the most cost-effective routine immunological reagents, such as various tag antibodies, internal reference antibodies, conventional primary antibodies and a full range of secondary antibodies, antibody detection substrates, protein purification products and Related kits, etc. At the same time, as a Chinese agent or regional agent of many international famous brands, Aimei can provide you with a series of laboratory solutions. If you are interested in the above products, please call the free customer line.

400-6800-868

Contact Amytech Co., Ltd. for product information and complete experimental solutions.

Manual Motor Starter

The Manual Motor Startor is Korlen electrical appliances anther products. manual motor startor overload relay is in main circuit of long time working. It is used to protect AC three-phase asynchronous motor against overload and open phase. It conformity with IEC947-4, VDE0660,GB14048.4 standards . As a motor starter switch in china ,korlen will do the best electrical motor controls for customers.
The Manual Motor Startor related products have the following: Thermal Relay , AC Contactor, led light, Circuit Breaker etc.

Manual Motor Starter,Motor Starter,KNS12,China Motor Starter

Wenzhou Korlen Electric Appliances Co., Ltd. , https://www.korlen-electric.com

This entry was posted in on